Container home · Layouts and floor areas

Container home designs and layout ideas

Compare container home designs by the rooms you need, the module size and the arrangement on your plot. These container home plans are layout studies, not approved building plans. Choose the number of containers and levels to calculate bare-shell internal area and ground footprint, then develop the finished rooms, insulation, services, stairs and access under the rules for the relevant UK nation.

Once you have found your configuration, compare suppliers: a single request to compare quotes from several professionals. ContainerBook does not build or sell homes.

A 40ft container: bare-shell internal area
28.3 m²
For 100 m² of bare-shell internal area
4 × 40ft or 8 × 20ft
4 × 40ft on two levels
59.4 m² footprint

Bare-shell internal area before insulation; not a finished dwelling area or space-standard assessment.

Calculate the space for your container home plans

20ft or 40ft module, from 1 to 12 containers, single-storey or two-storey: the calculation gives bare-shell internal area, volume and footprint. It does not calculate a permission exemption, finished room layout or compliance with a dwelling space standard.

Your configuration

Choose the module, number of containers and levels. The result updates with each choice.

Module
Levels

Calculation based on the dimensions of the reference models on the 20ft and 40ft pages. Bare-shell floor area: internal length × internal width, before insulation, partitions and cut-outs. Footprint: modules placed with no gaps or overhang, using external dimensions. No price is calculated.

Calculated areas

4 containers of 40ft standard, single-storey, modules side by side. These dimensions do not determine planning permission or building regulations approval.

Bare-shell internal area
113.2 m²
Ground footprint
118.9 m²
Internal volume
270.8 m³
Buy the 4 containersPrepare for installation and delivery

Request a free, no-obligation quote: the format and quantity are carried over into the form. ContainerBook does not build or sell container homes.

Planning and building checks

These figures describe container geometry before insulation and partitions. They do not determine permission. Check the site, proposed use, design and national rules with the local planning authority and building control or building standards service. Planning permission and building regulations

Your project, several professionals.

Have a configuration in mind? Get competitive quotes.

Same number of modules, same floor area: the price of the containers, their conversion and installation differs from one professional to another. Comparing several quotes prepared on the same basis is the most direct way to influence the price.

Independent supplier matching service, free for the requester.

  • Multiple quotes, one request.Describe your project once, instead of repeatedly contacting each seller or converter, to get proposals you can compare.
  • Comparable prices, line by line.Containers, conversion, transport, lifting and installation priced separately: you see where the difference lies, and you can negotiate.
  • Free and without obligation.You compare, then choose freely. ContainerBook neither builds nor sells homes.

How many containers for 40, 60, 80, 100 or 150 m²?

For a home of 100 m² bare-shell internal area, you need 4 40ft containers (113.2 m²) or 8 20ft containers (111.0 m²), before insulation and partitions. The table shows the smallest number of modules that reaches each floor area.

Number of containers for a target bare-shell internal area
Target area40ft standard20ft standard
40 m²2 containers56.6 m² bare-shell area3 containers41.6 m² bare-shell area
60 m²3 containers84.9 m² bare-shell area5 containers69.4 m² bare-shell area
80 m²3 containers84.9 m² bare-shell area6 containers83.3 m² bare-shell area
100 m²4 containers113.2 m² bare-shell area8 containers111.0 m² bare-shell area
150 m²6 containers169.8 m² bare-shell area11 containers152.6 m² bare-shell area

The 40ft High Cube gives the same number of modules as the standard 40ft for each of these floor areas: its extra height does not create additional floor area (28.3 m² of bare-shell internal area per module).

And for a small container home of about 20 m²: 1 × 40ft container (28.3 m²) or 2 × 20ft containers (27.8 m²); a single 20ft offers 13.9 m².

Home of 2, 3, 4, 5 or 6 containers: areas and footprints

Standard 40ft containers: calculated bare-shell internal area and ground footprint
ConfigurationBare-shell internal areaSingle-storey footprintTwo-storey footprint
2 × 40ft56.6 m²59.4 m²29.7 m²
3 × 40ft84.9 m²89.2 m²59.4 m²
4 × 40ft113.2 m²118.9 m²59.4 m²
5 × 40ft141.5 m²148.6 m²89.2 m²
6 × 40ft169.8 m²178.3 m²89.2 m²

These are bare-shell internal areas: internal length × width of the containers, before insulation, partitions, cut-outs and reinforcements. The finished habitable area is calculated on the project plan. The number of bedrooms depends on that plan: this page does not state any.

20ft, 40ft or High Cube?

The dimensions of each size remain on their pages. Three comparisons are enough to choose the module for a home.

One 40ft or two 20ft containers

One standard 40ft offers 28.3 m² of bare-shell internal area. Two 20ft provide 27.8 m², slightly less than a single 40ft: placed end to end, they count the walls and end doors twice.

Standard or High Cube

Same bare-shell floor area per module (28.3 m²), but 30.5 cm more internal height on the reference models: 76.3 m³ instead of 67.7 m³ per module.

Fewer modules to install

For 100 m² of bare-shell internal area: 4 40ft modules or 8 20ft modules, i.e. 4 more modules to deliver, lift and connect together.

Transport and offloading

Container home designs: single-storey, L-shaped, U-shaped or two-storey

The bare-shell internal floor area depends only on the size and number of modules. The footprint depends on how they are placed. Compare each arrangement with the rooms, circulation and outdoor space you want; these diagrams show module positions rather than a finished room plan.

Side by side

Footprint: 118.9 m²

L-shaped

Footprint: 118.9 m²

U-shaped

Footprint: 118.9 m²

Two-storey

Footprint: 59.4 m²

Top views of 4 40ft containers, to scale of their external dimensions. Bare-shell internal area: 113.2 m² in all four cases. Footprint calculated without clearance, overhang or terrace; the dashed modules are upstairs.

To help you visualise each shape: the top views above are the calculated plans; the illustrations below give an idea of the appearance, without plan value.

Illustration of a single-storey container home in anthracite grey containers, with large glazed openings, timber cladding and a terrace on a plot in the countryside
Single-storey home: containers placed side by side form a single volume. AI-generated illustration: not an actual build or a plan.
Top view illustration of an L-shaped container home, light grey containers around a timber terrace, in a Mediterranean garden
L-shaped home: a sheltered terrace in the corner. AI-generated illustration: not an actual build or a plan.
Top view illustration of a U-shaped container home, green and white containers around a timber patio, with a swimming pool in the foreground
U-shaped home: rooms open onto a central patio. AI-generated illustration: not an actual build or a plan.
Illustration of a two-storey container home, dark blue stacked containers, large windows, external metal staircase and balcony, on a plot in a residential development
Two-storey: floor area increases without enlarging the footprint. AI-generated illustration: not an actual build or a plan.

Single-storey, L-shaped or U-shaped

Placed on the ground without overlapping, 4 40ft containers occupy 118.9 m², in a line, L-shape or U-shape. The shape changes the site footprint (courtyard, passageways), the light and the number of walls to cut out to connect the modules. The builder's quote must describe these cut-outs and the planned reinforcements.

Two-storey

Stacked in pairs, the same 4 modules keep 113.2 m² of bare-shell internal area for 59.4 m² of footprint. With an odd number, one extra module stays at the bottom: 3 containers on two levels occupy also 59.4 m². Stacking requires checking the structure, supports and staircase.

Allow for the space lost inside the steel shell

Internal insulation, linings and services reduce clear width, area and headroom. The example below uses a rectangular 40ft shell and the same assumed build-up on each of its four walls; these thicknesses are geometric examples, not an insulation specification.

Illustrative 40ft standard: wall build-up only, before partitions, stairs and structural members
Build-up at each wallClear internal widthRemaining rectangle
Bare shell2.352 m28.3 m²
100 mm2.152 m25.5 m²
150 mm2.052 m24.1 m²
200 mm1.952 m22.7 m²

External insulation changes these geometry assumptions, but its thickness, roof detailing, boundaries and cladding still need to appear on the design and application drawings. A High Cube gives more initial height; it does not establish compliant finished headroom by itself.

England example: where the nationally described space standard applies through planning policy, a one-storey one-bedroom one-person dwelling is 39 m², or 37 m² with a shower room. A single reference 40ft shell is smaller even before lining. The standard also includes storage, room-width and height criteria; it is not a UK-wide minimum or a permission threshold.

Planning and building regulations

Container size alone does not determine permission. Ask the local authority about the actual site, proposed use, duration, access and protected status.

England

Planning. Plan a new independent container home as a dwelling application, including any change from the land's existing use. England's Class E garden-outbuilding rights cover incidental use: they do not authorise erecting separate self-contained accommodation or primary living accommodation. An annexe linked to an existing household requires its own assessment; calling it a garden room does not settle the use.

Building control. Obtain building regulations approval separately from planning. Agree the building control route and coordinated design before fabrication. Identify the competent designers and contractors and who acts as principal designer and principal contractor where the dutyholder arrangements apply. Domestic clients have specific arrangements, including default allocation of these roles; building-regulations roles and CDM health-and-safety roles are distinct.

Wales

Planning. Use the Welsh planning system and the local development plan for the plot. Welsh garden-outbuilding rights concern purposes incidental to the house; they are not an automatic route to a separate container dwelling. The Welsh siting and height rules differ from England's, so do not reuse an English permitted-development checklist.

Building control. Make a separate building regulations application using Welsh guidance. Investigate foul and surface-water drainage before fabrication. The 2026 SuDS guidance generally requires separate SAB approval for construction covering at least 100 m² with drainage implications, subject to exemptions and transition rules. Assess the whole construction area, including associated surfaces, rather than the container floor alone, and obtain required SAB approval before work starts.

Scotland

Planning. Discuss the dwelling and site with the council under the Scottish planning system. The development plan includes NPF4 and the local development plan. Rural-home proposals need the relevant policy assessment, including NPF4 Policy 17; owning a croft or a field, or reusing a steel shell, does not by itself establish consent.

Building warrant. A new home requires a building warrant. Obtain it from the council verifier before building work starts, and obtain an approved amendment before making a design change that needs one. Follow the Construction Compliance and Notification Plan for inspections and notifications, including work completed off site.

Northern Ireland

Planning. Apply through the council's planning service for a separate dwelling. nidirect expressly identifies a separate house in a garden, or a garden building or caravan used as a separate residence, as requiring an application. Assess the council's development plan and the applicable countryside policies where the site is outside a settlement.

Building control. Contact the district council's building control service for the separate building regulations application and inspections. Use the Northern Ireland Building Regulations and Department of Finance Technical Booklets. Ask the council to agree the evidence for this non-standard construction before manufacture and installation.

Obtain a national compliance schedule for the finished design. The detailed guide covers current technical documents, commencement dates and the evidence needed for completion.

Planning and building checks for your project

Use the right area for the drawing and application

The calculator describes container geometry. The designer must measure the finished proposal using the definitions required for its planning application, national building calculations and any applicable space standard.

Bare-shell internal area
What this page calculates: internal length × width of each container, added together, before insulation, partitions, cut-outs and reinforcements. It is used to compare configurations.
Ground footprint
Calculated here from the external dimensions of modules placed without clearance or overhang. A canopy, a covered terrace or an offset between modules changes the actual footprint.
Finished dwelling area
Measure to the boundaries defined by the applicable method. England’s NDSS gross internal area includes partitions and structural elements within the enclosing perimeter; it is not the sum of room clear areas. Energy assessments and other national rules may use their own conventions.

Ask for dimensioned finished drawings, the area measurement method and room-by-room usable dimensions. Keep the bare-shell calculation separate from the planning and building-control area schedules.

Questions about container home floor plans

How many containers for a home of 100 m²?
For a home of 100 m² bare-shell internal area, you need 4 40ft containers (113.2 m²) or 8 20ft containers (111.0 m²), before insulation and partitions. The 40ft High Cube gives the same number of modules as the standard 40ft. This is an area before insulation, partitions and cut-outs: the floor area and the living area are calculated from the project plan, prepared and checked by the project designer.
Single-storey or two-storey container home: what changes?
The bare-shell internal area does not change: 113.2 m² for 4 40ft containers. The ground footprint changes from 118.9 m² on one level to 59.4 m² on two levels. Stacking modules requires the structure, supports and upper-floor access to be checked by the manufacturer or structural engineer. Planning permission requirements should be confirmed with the local planning authority.
Do you need High Cube or standard containers for a home?
On the reference models, a 40ft High Cube offers the same bare-shell floor area as a standard 40ft (28.3 m² before insulation) and 30.5 cm of extra internal height, i.e. 76.3 m³ instead of 67.7 m³. This height leaves room to insulate the floor and ceiling. It does not change the number of modules needed for a given area.

The container home guide

Updated · Guidance reviewed · No prices, no planning conclusions